무제 문서




TDC7200 이벤트 시간-디지털 변환 모듈

(TDC CLICK)

 

개요

  • 본 제품은 TDC7200 이벤트 시간-디지털 변환 모듈 입니다.
  • 이벤트를 인식하고 이벤트가 일어난 시간을 디지털로 변환하여 주는 제품으로 TDC7200 기반으로 디자인된 제품입니다.
  • 스탑워치의 기능과 START 펄스와 5개까지의 STOP 펄스 사이의 경과 시간 (Time of Flight)을 측정하고자 하는 경우 사용이 가능한 제품입니다.
  • ToF 나 흐름 측정 어플리케이션 등에 사용이 가능한 제품입니다.

특징

  • TDC Click as its foundation uses the TDC7200, a time-to-digital converter for time-of-flight (ToF) applications for LIDAR and ultrasonic from Texas Instruments. This stopwatch IC is used to measure the time between a single event known as time-of-flight (an edge on START signal) and multiple subsequent events (an edge on STOP signal), which are brought to the onboard SMA connectors marked as START and STOP. The user also can pair this Click board™ with some external board that contains the TDC1000 (ultrasonic analog front-end) and become a part of a complete ultrasonic sensing solution for measurements such as water, gas, and heat flow meter.

    TDC Clikc inneri

    The TDC7200 has an internal self-calibrated time base which compensates for drift over time and temperature used to measure time with accuracy in the order of picoseconds. When placed in the Autonomous Multi-Cycle Averaging mode of operation, the TDC7200 can be optimized for low system power consumption. The host can go to sleep to save power, and the TDC can wake it up upon completion of the measurement sequence.

    The TDC7200 also needs an external reference clock used to calibrate the internal time-base accurately. All digital circuits inside the device also use this reference clock; thus, the clock has to be available and stable at all times when the device is enabled. For this reason, there is the possibility of selecting an external clock connected to a miniature coaxial N.FL series connector or an internal one by an onboard 8MHz crystal that can be activated via an OEN pin routed on the AN pin of the mikroBUS™ socket. Selection can be performed by onboard SMD jumper labeled as CLK SEL to an appropriate position marked as EXT and INT.

    The TDC7200 communicates with MCU using the standard SPI serial interface with a maximum frequency of 20MHz. In addition, it also uses several additional GPIO pins such as the EN pin routed on the RST pin of the mikroBUS™ socket used as a reset to all digital circuits in the TDC7200, TRG pin routed on the PWM pin of the mikroBUS™ socket as a start measurement trigger and INT pin which determine TDC measurement completion.

    This Click board™ can be operated only with a 3.3V logic voltage level. The board must perform appropriate logic voltage level conversion before use with MCUs with different logic levels. However, the Click board™ comes equipped with a library containing functions and an example code that can be used, as a reference, for further development.

  • Type Clock generator
    Applications Can be used for time-of-flight and flow meter applications where zero and low flow measurements require high accuracy
    On-board modules TDC7200 - time-to-digital converter for time-of-flight (ToF) applications for LIDAR and ultrasonic from Texas Instruments
    Key Features Low power consumption, Autonomous Multi-Cycle Averaging mode, SPI interface for configuration and register access, supports up to 5 STOP signals, internal self-calibrated time base which compensates for drift over time and temperature, and more
    Interface SPI
    Compatibility mikroBUS
    Click board size M (42.9 x 25.4 mm)
    Input Voltage 3.3V