2채널 CAN/LIN 버스 데이터 로거 / CAN-USB 컨버터 CANEDGE1

(CANEDGE1: 2X CAN BUS DATA LOGGER (SD + RTC))

개요

  • 본 제품은 플러그&플레이 2채널 CAN/LIN 데이터 로거입니다.
  • 타임스탬프가 찍힌 CAN 데이터(Classical/CAN FD)를 8-32GB SD 카드에 저장할 수 있는 제품입니다.
  • 매우 사용하기 편한 제품으로 CAN 버스 커넥터를 통해 장치에 전원을 공급하고 raw CAN 데이터를 로깅하는 것을 시작할 수 있습니다.

특징

  • GENERAL
    Functionality Standalone data logger with SD card and 2xCAN/LIN channels (incl. CAN FD)
    Firmware Supports free firmware updates for adding features
    Configuration Configuration files based on the popular open source JSON schema concept
    Software Free open source editor tool for easy device configuration (offline/online version available)
    Free open source asammdf software & API for editing, DBC converting & plotting MDF4 data
    Free open source C++ MDF4 converters - drag & drop log files to convert into e.g. CSV, ASC, PCAP
    Safety CE, FCC, IC and RoHS certified (see the manual)
    Tested for voltage transients (emissions/immunity), ISO 7637-2:2011, by TÜV SÜD (see the manual)
    Support Free, fast & high quality support
    Origin Denmark
    CAN BUS
    Channels 2 x CAN/CAN FD channels
    Standard ISO 11898: Compliant with CAN (up to 1 Mbit/s) and ISO & Bosch CAN FD (up to 5 Mbit/s)
    Protocols Log raw data from CAN based protocols (J1939, FMS, CANopen, NMEA 2000, OBD2, ...)
    Identifiers Compliant with CAN specifications 2.0A (11-Bit ID) and 2.0B (29-Bit ID)
    Bit-Rate Auto-Detect Bit rate can be auto-detected or set manually
    Retransmission Configurable retransmission of frames that have lost arbitration or been disturbed by errors
    Transceiver Protection ±16 kV HBM ESD, ±15 kV IEC ESD, ±70 V bus fault, short circuit
    Common mode input voltage: ±30 V
    TXD dominant timeout (prevents network blocking in the event of a failure)
    LIN BUS
    Channels 2 x LIN channels (Slaves)
    Standard Compliant with LIN 2.0 up to 20 Kbit/s ("enhanced" checksum format)
    Transceiver Protection ±8 kV HBM ESD, ±1.5 kV CDM, ±58 V bus fault
    TXD dominant timeout (prevents network blocking in the event of a failure)
    DATA LOGGING
    SD Card 8 GB extractable Class 10 industrial micro SD (SDHC) included (optional 32GB) - read at 80 MB/s  
    Parallel CAN/LIN Record data from up to 2 x CAN channels + 2 x LIN channels, simultaneously
    Real-Time Clock Yes - CAN frames are date & timestamped with 50 microsecond resolution
    The RTC can be configured to match local time zones (default: UTC)
    Log File Format Log data in industry standard binary MDF4 (easily convert to e.g. CSV, ASC, pandas, MATLAB, ...)
    Data Compression Configurable embedded log file zipping (~50-80% size reduction)
    Silent Mode Configurable silent mode: Restricted (acknowledge only) or monitoring (zero transmission)
    Filters 128/64 regular/extended ID filters per channel (range, mask, acceptance, rejection, prescaling)
    Transmit Transmit lists of CAN frames per channel (single-shot/periodic) - e.g. for OBD2 requests
    Cyclic Logging Optional cyclic logging mode (oldest log file is deleted when SD card is full)
    Advanced Triggers Control signal lets you start/stop logging based on custom CAN IDs & data thresholds
    CAN Heartbeat Optionally transmit heartbeat CAN frame with device status, storage used & RTC time
    File Split Configurable log file split size (by size: 1-512 MB and/or by time period: 0-86400s)
    Power Safe 100% power safe data logging - no file corruption when disconnected
    Unique Device ID Each device has a globally unique ID ensuring unique log file naming
    Data Encryption Log files can be encrypted at rest on the SD card for security/GDPR/CCPA purposes
    ELECTRICAL/SUPPLY
    Via CAN bus Power supplied by the CAN bus (+7V to +32V DC) via the Channel 1 DB9
    Power Consumption Extremely low (~1 W) - no risk of battery drainage
    Protection Reverse voltage protection on CAN-bus supply
    Transient voltage event protection on supply lines
    MECHANICAL
    Enclosure & Weight Compact aluminium enclosure: 52.5 x 81.4 x 24.5 mm (L x W x H), 100 grams
    Connector 2 x Standard D-sub 9 (DB9) connectors (OBD2/J1939 adaptors optional)
    Pin-Out See the product manual for the DB9 connector pin-outs
    Configurable Power Out Channel 2 can be configured to supply 5V to 1-3 external modules
    LEDs Logger status via 4 external LEDs: Power, CH1, CH2, Memory
    Temperature Operating temperature (parts): -25degC to +70degC
    IP Rating IP Rating 40