Average current consumption: 12 mA (note: this sensor draws current in large, short bursts, and the manufacturer recommends putting a 10 µF capacitor or larger across power and ground close to the sensor to stabilize the power supply line)
Distance measuring range: 2 cm to 15 cm (0.8″ to 6″)
Output type: analog voltage
Output voltage differential over distance range: 1.65 V (typical)
Update period: 16.5 ± 4 ms
Size: 27 mm × 13.2 mm × 14.2 mm (1.06″ × 0.52″ × 0.56″)